- Project Runeberg -  Den Norske Nordhavs-expedition 1876-1878 / The Norwegian North-Atlantic Expedition 1876-1878 / 2. Bind /
38

(1880-1901) [MARC]
Table of Contents / Innehåll | << Previous | Next >>
  Project Runeberg | Catalog | Recent Changes | Donate | Comments? |   

Full resolution (JPEG) - On this page / på denna sida - Sidor ...

scanned image

<< prev. page << föreg. sida <<     >> nästa sida >> next page >>


Below is the raw OCR text from the above scanned image. Do you see an error? Proofread the page now!
Här nedan syns maskintolkade texten från faksimilbilden ovan. Ser du något fel? Korrekturläs sidan nu!

This page has never been proofread. / Denna sida har aldrig korrekturlästs.

I Polarstrømnien aftager Temperaturen langtsonist
med Dybet. Her skulde Vendethermometrene. der tjene
som Normaler for Bestemmelsen af Trykcorrectionerne,
være bedst accommoderede, det er forholdsvis mest
at’kjo-lede, vise forholdsvis lavere, og folgelig
Indexthernioinetrc-nes Trykcorrection vise sig større. Som man ser. er
Tryk-correctioiien i Polarstroiiinien fundet numerisk mindre end
i den varme Strom. Man tor altsaa, som ovenfor Side 15
bemerket, antage, at Vendetliermonietrene have
’acconuuo-deret sig fuldstændig efter Bundtemperaturen uagtet
Kassernes tabte Flydeevne.

Den Nnjagtighed. med hvilken de for Skalafejl og
Tryk reducerede Therniometeraflæsninger angive den
rigtige Temperatur i Dybet, kan man faa en Forestilling 0111
efter Storreisen af Middelfejlen for Trykcorreetiouens
Bestemmelse ved de forskjellige Indexthérmoinetre. da denne
Bestemmelse indeslutter Skalacorrectionens Fejl. For
Veiide-thermometrenes Vedkommende haves det samme Maal i
Middelfejlen af Sammenligningerne med
Normalthermonietret. Opstilles de nævnte Værdier af Middelfejlen ved en
enkelt Teni])eraturbestemnielse. faar man følgende Oversigt.

In the Polar current, the temperature diminishes
most slowly with the depth. Here the iiiverting-thernionieters
serving as standards to determine the pressure-corrections,
should prove best accomodated, i. e. comparatively most
cooled, viz. read relatively lower, and hence the
pressure-correction of the index-thermometers be greater. As will
be seen, the pressure-correction in the Polar current was
found numerically less than in the warm current. We may
therefore assume, as previously remarked, p. 15. that the
iiiverting-thernionieters had become thoroughly accomodated
in the bottom-temperature, notwithstanding the lost
buoyancy of the frame.

The accuracy with which the thermometer-readings
reduced for errors of scale and pressure, indicate the exact
temperature in the deep strata, can be found by the magnitude
of the mean error of the pressure-correction for the
different index-thermometers, since that correction contains
within it the error in the scale-correction. As regards the
iiiverting-thernionieters. we have the same standard in the
mean error ol’the comparisons with the Standard-Thermometer.
Now. if we put down the said values of the mean error
of a single determination of temperature, the result will be
as follows,

Thermometer. Mr.

Miller-Casella 1. + o°.o6i

II. o .072

,, III. 0.13Q

,. .. IV. 0.020

r V. o .072

VI. o .064

VII. o .050
IX. o .035

Buch. Kv. (Mere.) Piezom. o .067

Casclla-Bueh. 4t>. o .054

48. o .071

45). o .070

Negr. & Zanib. 80. o .026

„ „ 91. o .047

Middel (Mean)

Middel for Indexthermonietrene er + o0.oÖ4.

,. Vendethermometrene er + o .037.

Da den sidste Verdi indgaar i Bestemmelsen af den
förste bliver Middelfejlen for en Temperaturbestemmelse
med et Indexthermometer

+ v 0.0642 — o .037- = + O0.O52.

Ogsaa paa folgende Maade kan man bedømme
Teni-peraturbestem 111 eisernes Nøjagtighed. I 1878 sendtes ofte
3 Dybvandsthernioinetre. 2 Index- og et Vendetlicrinoineter
(i Regelen No. 89) med Loddet til Bunds. Tager man
Middel af disse 3 Thermometres for Skalafejl og Tryk
cor-rigerede Angivelser, og beregner Afvigelsen mellem de en-

+ o". 061

Mean for the index-thermometers + o".o64.
„ inverting-thermonieters + o .037.

The last of these values being contained in the
determination of the first, the mean error of a determination
of temperature with an index-thermometer will lie
.+ 1 0.064- — o .037-’ rr + 0".052.

Also in another manner can the accuracy of the
temperature-determinations be estimated. I11 1878, 3
deep-sea thermometers, 2 index and 1 invertiiig-therniometer (as
a rule No. 89), were sent to the bottom with the lead.
Now, if we take the mean of the indications of these 3
thermometers, corrected for errors of scale and pressure,

<< prev. page << föreg. sida <<     >> nästa sida >> next page >>


Project Runeberg, Sun Dec 10 20:01:49 2023 (aronsson) (download) << Previous Next >>
https://runeberg.org/nordhavexp/2/0222.html

Valid HTML 4.0! All our files are DRM-free