- Project Runeberg -  Elektronikens grunder / 1. Passiva komponenter och konstruktionselement /
179

(1966-1968) [MARC] Author: John Schröder
Table of Contents / Innehåll | << Previous | Next >>
  Project Runeberg | Catalog | Recent Changes | Donate | Comments? |   
Note: This work was first published in 1966, less than 70 years ago. John Schröder died in 1998, less than 70 years ago. Therefore, this work is protected by copyright, restricting your legal rights to reproduce it. However, you are welcome to view it on screen, as you do now. Read more about copyright.

Full resolution (JPEG) - On this page / på denna sida - 8. Ferromagnetiska material - Kopplingskärnor - Transfluxorer

scanned image

<< prev. page << föreg. sida <<     >> nästa sida >> next page >>


Below is the raw OCR text from the above scanned image. Do you see an error? Proofread the page now!
Här nedan syns maskintolkade texten från faksimilbilden ovan. Ser du något fel? Korrekturläs sidan nu!

This page has never been proofread. / Denna sida har aldrig korrekturlästs.

Fig. 825

En kärna med rek-
tangulär = hysteres-
slinga kan omkopp-
las stegvis från —B,
till +Bs. |

Fig. 826
2-hålstransfluxor-
kärnans <:uppbygg-
nad.

lindning anbringad på kärnan. Kopplingskärnor används i lo-
giska kretsar, i frekvensdelare, elektroniska räknare m. m.

Om en kopplingskärna matas med korta pulser på sådant
sätt att fullständig ommagnetisering inte uppstår för varje puls
kan man åstadkomma en stegvis ommagnetisering av kärnan,
se fig. 825.

Transfluxorer

Transfluxorer är utformade som kärnor med flera magnetiska
kretsar. I 2-hålstransfluxorn, se fig. 826, styres kärnans mag-
netiska egenskaper av en styrlindning S anbringad i ett ”styr-
hål”.